CHKNL - MEDIUM DRY AQUEOUS RECORDER INK, 61101BMA

  • MSDS: CHKNL
  • Manufacturer: GRAPHIC CONTROLS CORP
  • Product Name: MEDIUM DRY AQUEOUS RECORDER INK, 61101BMA
  • National Stock Number: 7510-00N086345
Product Identification

Product ID:MEDIUM DRY AQUEOUS RECORDER INK, 61101BMA
MSDS Date:06/05/1996
FSC:7510
NIIN:00N086345
MSDS Number: CHKNL

Responsible Party
GRAPHIC CONTROLS CORP
ONE CARNEGIE PLAZA
CHERRY HILL, NJ 08003-1002
US

Emergency Phone: 800-669-4428;800-424-9300(CHEMTREC)

Info Phone: 609-424-2200

Preparer: GEORGE SARKISIAN

Cage: 17405

Contractor
GRAPHIC CONTROLS CORP INDUSTRIAL PRODUCTS DIVISION
1309 BUFFALO, NY 14240 US

Telephone: 716-853-7500

Cage: 17405

Ingredients

AMMONIUM,

CAS: 1694-09-3

RTECS: BQ1140000

Fraction By Weight: 0.5-1.5%

OSHA PEL N/K

ACGIH TLV: N/K


98.5 - 99.5

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: >98.5%

OSHA PEL N/K

ACGIH TLV: N/K


NON-HAZARDOUS INGREDIENTS

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50 (ORAL, RAT): >5 GM/KG
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN: CAN CAUSE IRRITATION AND
SKIN STAINING. EYES: CONTACT MAY CAUSE IRRITATION. INHALATION:
INHALATION OF VAPORS MAY RESULT IN RESPIRATORY IRRITATION.
INGESTION: MAY RESULT IN GASTRIC DISTURB ANCE. CHRONIC: NONE
EXPECTED BASED ON EMPLOYEE HISTORY OF EXPOSURE.
Explanation of Carcinogenicity:C. I. ACID VIOLET 49: IARC MONOGRAPHS,
SUPP VOL 7, PG 56, 1987: GROUP 2B.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES MINIMUM. IF
IRRITATION PERSISTS, GET PROMPT MEDICAL ATTENTION. SKIN: REMOVE
CONTAMINATED CLOTHING AND WASH SKIN THOROUGHLY WITH SOAP AND WATER.
INHAL: REM OVE PERSON TO FRESH AIR. AID BREATHING IF NECESSARY AND
GET MEDICAL ATTENTION. INGESTION: IF SWALLOWED, DILUTE WITH WATER
AND INDUCE VOMITING. GET MEDICAL ATTENTION.

Fire Fighting

Flash Point:NOT FLAMMABLE
Extinguishing Media:USE MEDIA PROPER TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:WIPE UP SPILLS WITH TOWELS OR CLOTHS. REMOVE
STAINS WITH SOAPY WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NO SPECIAL REQUIREMENTS.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:NIOSH APPROVED ORGANIC VAPOR RESPIRATOR, IF
VAPORS OR MIST ARE GENERATED.
Ventilation:MECHANICAL (GENERAL) VENTILATION IS SATISFACTORY.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VAPOR DENSITY: DUE TO H*20 ONLY.

Chemical Properties

Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:DUE TO H*20 ONLY
Vapor Density:SUPDAT
Spec Gravity:1.038-1.055 (H*2O=1)
pH:4.0-8.0
Evaporation Rate & Reference:DUE TO H*2O ONLY
Solubility in Water:COMPLETE
Appearance and Odor:BLACK, RED, BLUE, GREEN, ORANGE, PURPLE; SLIGHT
CHARACTERISTIC ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
REACTS WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:ACROLEIN.

Disposal

Waste Disposal Methods:WASTE DISPOSAL SHOULD BE IN ACCORDANCE WITH
EXISTING FEDERAL, STATE, AND LOCAL ENVIRONMENTAL CONTROL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.